SWNLEU1 Netherlands #1, AMSTERDAM, Netherlands, Europe
-
Capacity
- Total datafloor 5000 m2 (53,800 Square Feet)
- Room for upto 75 000 servers Access
- Proximity Card Access
- Video security in and around the building
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets Staff
- 24/7 On-Site Security Staff
- 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 4kW per Cabinet
- 4 backup power generators of 8 MVA each
- UPS
- Diesel storage 50 000 liters onsite
- Utility Power 15 MW, 2 substations
- Power Distribution - 2N Redundant A and B feeds Cooling
- CRAC - 8x 30 Ton Units per suite, N+2
- Chillers - Building provided redundant chilled water
- Raised floor construction
- Hot/Cold corridor system Fire Suppression
- Aspiration Smoke Detection Apparatus
- VESDA Particulate Detection
- MIST fire suppression system Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
- Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
-
Transport Services:
- Metro fiber services to nearly all Carrier Neutral facilities in Amsterdam over Swiftways own DWDM redundant fiberring.
- Fiber to various datacenters in the Netherlands
- Long Haul to various International datacenters
- Ipv4 and Ipv6 available
SWCHUSA1 CHICAGO #1, USA
-
Capacity
- Total datafloor 1500 m2 (16,000 Square Feet)
- Room for upto 25 000 servers Access
- Proximity Card and Biometric Access
- Video security in and around the building
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets Staff
- 24/7 On-Site Security Staff
- Staff - 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 12kW per Cabinet
- 2MW + 1MW Caterpillar Generators
- UPS
- Utility Power into the building 100+ MW, 3 sub-stations
- Power Distribution - 2N Redundant A and B feeds Cooling
- CRAC - 16x 20 Ton Liebert Units, N+1
- Chillers - Building provided redundant chilled water Fire Suppression
- VESDA Particulate Detection
- Clean Agent Extinguishers
- Pre-Action Dry Pipe Sprinkler Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
-
Transport Services
- Chicago metro fiber services
- Long-haul services to New York City
- Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
- Ipv4 and Ipv6 available
SWFMTUSA#1 FREMONT #1, CALIFORNIA, USA
-
Capacity
- Total datafloor 18500 m2 (200,000 Square Feet)
- Room for up to 400 000 servers Access
- Proximity Card Access
- Custom designed video surveillance of every single cabinet
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets
- Staff
- 24/7 On-Site Security Staff
- Staff - 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 2 kW per Cabinet
- N+1 Generators
- UPS
- Power Distribution - A feeds only Cooling
- N+1 per suite.
- Chillers - Building provided redundant chilled water
- Raised floor construction
- 50 Cubic Feet per Minute fan installed in every cabinet Fire Suppression
- VESDA Particulate Detection
- Clean Agent Extinguishers
- Pre-Action Dry Pipe Sprinkler Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
-
Transport Services
- Long-haul services to San Jose - Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
- Ipv4 and Ipv6 available
Copyright © 2011 Swiftway. All rights reserved.
Permission is given to view, copy, print, and distribute material
on this Web site subject to the conditions.
This website is an archival preservation of material formerly published at swiftway.net. It is not affiliated with, endorsed by, or operated by any business or organisation currently using that name. No orders, bookings, enquiries or applications are accepted here, and no personal information is collected.