SWNLEU1 Netherlands #1, AMSTERDAM, Netherlands, Europe
-
Capacity
- Total datafloor 5000 m2 (53,800 Square Feet)
- Room for upto 75 000 servers Access
- Proximity Card Access
- Video security in and around the building
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets Staff
- 24/7 On-Site Security Staff
- 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 4kW per Cabinet
- 4 backup power generators of 8 MVA each
- UPS
- Diesel storage 50 000 liters onsite
- Utility Power 15 MW, 2 substations
- Power Distribution - 2N Redundant A and B feeds Cooling
- CRAC - 8x 30 Ton Units per suite, N+2
- Chillers - Building provided redundant chilled water
- Raised floor construction
- Hot/Cold corridor system Fire Suppression
- Aspiration Smoke Detection Apparatus
- VESDA Particulate Detection
- MIST fire suppression system Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
- Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
-
Transport Services:
- Metro fiber services to nearly all Carrier Neutral facilities in Amsterdam over Swiftways own DWDM redundant fiberring.
- Fiber to various datacenters in the Netherlands
- Long Haul to various International datacenters
- Ipv4 and Ipv6 available
SWCHUSA1 CHICAGO #1, USA
-
Capacity
- Total datafloor 1500 m2 (16,000 Square Feet)
- Room for upto 25 000 servers Access
- Proximity Card and Biometric Access
- Video security in and around the building
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets Staff
- 24/7 On-Site Security Staff
- Staff - 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 12kW per Cabinet
- 2MW + 1MW Caterpillar Generators
- UPS
- Utility Power into the building 100+ MW, 3 sub-stations
- Power Distribution - 2N Redundant A and B feeds Cooling
- CRAC - 16x 20 Ton Liebert Units, N+1
- Chillers - Building provided redundant chilled water Fire Suppression
- VESDA Particulate Detection
- Clean Agent Extinguishers
- Pre-Action Dry Pipe Sprinkler Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
-
Transport Services
- Chicago metro fiber services
- Long-haul services to New York City
- Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
- Ipv4 and Ipv6 available
SWFMTUSA#1 FREMONT #1, CALIFORNIA, USA
-
Capacity
- Total datafloor 18500 m2 (200,000 Square Feet)
- Room for up to 400 000 servers Access
- Proximity Card Access
- Custom designed video surveillance of every single cabinet
- 24x7 access for Swiftway colocation clients
- Individually locked cabinets
- Staff
- 24/7 On-Site Security Staff
- Staff - 24/7 On-Site Technical Support Staff Power
- Power Density - Up to 2 kW per Cabinet
- N+1 Generators
- UPS
- Power Distribution - A feeds only Cooling
- N+1 per suite.
- Chillers - Building provided redundant chilled water
- Raised floor construction
- 50 Cubic Feet per Minute fan installed in every cabinet Fire Suppression
- VESDA Particulate Detection
- Clean Agent Extinguishers
- Pre-Action Dry Pipe Sprinkler Network
- Fiber Diversity - Dual fully diverse fiber paths, building entry points, and in-building riser
-
Transport Services
- Long-haul services to San Jose - Internal Cabling Cat5e/Cat6/6a - Single Mode Fiber (SMF) - Multi Mode Fiber (MMF)
- Ipv4 and Ipv6 available